Measure Relaxed Spring Plate Angle

- After disconnecting the swing arm from the spring plate, measure the angle of the top edge so that it can be returned to the same position.
- There are 40 splines on the inner end and 44 splines on the outer end.
- If the spring plate is off by one spline it will change the angle shown by 8 deg 10 min.
- This change is greater than the 5 deg resolution of the measuring instrument.
- The instrument is a Craftsman Magnetic base Protractor - Surface Level
- It is available at Sears for less than $5.
|