logo
 Up

912 Manual Replace Hoses, Ducts and Gates



Air Hose Connecting Duct



Removal



912_fig_65 Detach heating hose.
912_fig_66 Show how to disconnect the Euro hoses.


Installation



912_fig_67 How to adjust the Euro Hose Installation


Installation



Installing Lower Duct with Air Gates



This is for the export heater. The following points should be observed when installing the lower air duct:
912_fig_68 The air gates, located in the lower air duct must be so adjusted that they perform the opening and closing functions in unison. Ensure that the large air gate flaps are positioned approx 10 mm (2/5in.) from the bottom of the ducts when the small air gate flap is fully closed. Upon mounting the lower ducts at the engine, check for proper functioning of the air gates and readjust if necessary.


Installing Air Gate Assembly



The following points should be observed when installing the air gate assembly:
912_fig_69 Check for proper seating of the 2,5 mm-thick cork gasket.

Check heating hose attachment for air-tightness and firm seating with the help of the hose clamp.
Last modified: Mon, 17 Jan 2005

 Links

Site Details. Disclaimer. Comments? Questions? Dave Hillman
Content attribted to others remains their property. Otherwise the text and images are licensed under a Creative Commons License.